Abstract

Background: The objective of this study was to compare the safety and efficacy of modified open technique and closed technique for gaining entry [primary trocar insertion] and establishing pneumoperitoneum in laparoscopic surgery.   

Methods: The present study was prospective, observational and longitudinal.  Protocol of the procedure was formed along with Performa, Patient Information Sheet and Informed Consent Form. The present study was carried out in surgery department of C.U Shah medical college, Surendranagar, Gujarat state. The study was carried out from 1st October 2012 till 31st May 2014. A total of two hundred patients undergoing emergency and elective laparoscopic surgery were included in our study.  Case records of  patients was recorded in the Performa containing demographic details, size and site of trocar insertion, technique of trocar insertion, intraoperative, early postoperative and late post operative complications were noted.

Results: Total of 200 cases was included in our study. The age of patients ranges from 10-70 years. Out of 200 cases 90% were females suffering from different ailments and 105 were males in group A while in Group b 80% were females and 20%were males.  In terms of on table complications; gastrointestinal injury is more in close method of trocar insertion.

Conclusions: We would advocate the modified open technique of trocar insertion as a technique of choice in primary trocar insertion as it is more efficacious and counts more on patient safety as compared to the close technique. 

References

Hamayun M, Saba N, Bilal M, Mehsud N. comparison of open versus closed pneumoperitoneum in laparoscopic surgery. Gomal J Med Sci. 2015;13:115-7.

Agresta F, DeSimon P, Gardo LF, Bedin N. Direct trocar insertion v/s verees needle in non obese patient undergoing laparoscopy procedure. Surgery Endosc. 18:1778-81.

Bernik Tr, Trocciola SM, Mayer DA, Patane J, Czura CJ, Wal- lack MK. Ball on blunt-tip trocar for laparoscopic cholecystectomy: improvement over the traditional Hasson and Veress needle methods. J Laparoendosc Adv SurgTech. 2001;11:73-8.

Bonjer HJ, Hazebroek EJ, Kazemier G, Giuffrida MC, Meijer WS, Lange JF. Open v/s closed establishment of pneumoperitoneum in laparoscopic surgery. Br J Surg. 1997; 84:599-602.

Merlin TL, Hiller JE, Maddern GJ, Jamieson GG, Brown Ar, Kolbe A. Systematic review of the safety and effectiveness of methods used to establish pneumoperitoneum in laparoscopic surgery. Br J Surg. 2003;90:668–79.

Pawanindra L, Sharma r, Chander J, ramteke VK. A technique for open trocar placement in laparoscopic surgery using the umbilical cicatrix tube. Surg Endosc. 2002;16:1366-70.

Carbonwll AM, Harold KL, Smith TI, Matther BD, Sing RF, Kercher KW et al. Umbilical stalk technique for establishing pneumoperitoneum. J Laproendosc Advan Surg Tech. 12(3):203-6.

Fitzgibbons RJ, Marsh RE. Method of creating a pneumoperitoneum. 2nd ed. Lipincott, Williams & Wilkins, Philadelphia. 2001:28-9.

String A, Berber E, Foroutani A, Macho JR, Pearl JM, Siperstein AE. Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures. Surg Endosc. 2001;15(6):570-3.

Rehan HS, Kakkar AK. 2010.

Merlin TL, Hiller JE, Maddern GJ, Jamieson GG, Brown AR, Kolbe A. Systematic review of the safety and effectiveness of methods used to establish pneumoperitoneum in laparoscopic surgery. British Journal of Surgery. 2003;90(6):668-79.

Agresta F, DeSimon P, Gardo LF, Bedin N. Direct trochar insertin v/s veress needle in non obese patient undergoing laparoscopy procedure. Surgery Endosc. 18:1778-81.

Champault G, Cazacu F, Taffinder N. Serious trocar accidents in laparoscopic surgery: a French survey of 103852 operations. Surg Laparosc Endosc. 1996;6:367-70.

Cogliandodlo A, Manganaro T, Saitta FP, Micali B. Blind v/s open approach to laparoscopic cholecystectomy: a randomized study. Surg Laparosc Endosc. 1998;8:353-5.

Hurd WW, Randolph JF, Holmbergr A, Pearl ML, Hubbell GP. Open laparoscopy without special instruments or sutures, comparison with a closed technique. J Reprod Med. 1994;39:393–7.

Lal P, Vindal A, Sharma R, Chander J Ramteke VK. Safety of open technique for first trocar placement in laparoscopic surgery; a series of 6000 cases, Surgical Endoscopy. 2012;26(1):182-8.

Antevil JL, Bhoyrul S, Brusuon ME, Vierra MA, Swadia MD. safe and rapid laparoscopic access. A new approach. World Journal of Surgery. 2005;29(6):800-3.

Taro A, Mannino M, Cappello G, Di Stefano A, Di Carlo I. Comparison of two entry methods for laparoscopic port entry: Technical point of view. Diagnostic and Therapeutic Endoscopy. 2012:305428:7.

Vilos GA, Ternamian A, Dempster J, Laberge P. Laparoscopic entry: a review of technique, technology and complications. J Obstet Gynecol. 2001;29(5):433-65.

Gray’s Anatomy 38th edition: umbilicus:850-1.

Downloads

Published

2016-12-24

How to Cite

Bathla, V., Thekdi, P. I., Koradia, P., Jhala, D., & Gadhvi, U. (2016). Comparative study of modified open technique and closed technique for primary trocar insertion in laparoscopic surgery. International Journal of Research in Medical Sciences, 4(1), 160–164. https://doi.org/10.18203/2320-6012.ijrms20160024